Diagnosis Procedure
- CHECK DOOR SWITCH CIRCUIT
Connect CONSULT and check the BCM input signals. Refer to Component Function Check .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace malfunctioning parts.
- CHECK COMBINATION METER INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "DOOR W/L" monitor value.
"DOOR W/L"
Door open
: On
Door closed
: Off
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER : Removal & Installation .
NO
Replace BCM. Refer to BCM : Removal & Installation .