Diagnosis Procedure
- CHECK TRUNK LID OPEN SIGNAL CIRCUIT
- Connect the CONSULT.
- Check the BCM input signals. Refer to Component Function Check .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace malfunctioning parts.
- CHECK COMBINATION METER INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "TRUNK/GLAS-H" monitor value.
"TRUNK/GLAS-H"
Trunk lid open
: On
Trunk lid closed
: Off
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER : Removal & Installation .
NO
Replace BCM. Refer to BCM : Removal & Installation .