Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Check that the following fuse is not blown (open).
Power source
Fuse No.
Capacity
Ignition switch ON
#93
5 A
Is the fuse blown (open)?
YES
Replace fuse after repairing the applicable circuit.
NO
GO TO 2.
- CHECK AROUND VIEW MONITOR CONTROL UNIT IGNITION POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between around view monitor control unit harness connector and ground.
(+)
(-)
Standard value
Reference value
Around view monitor control unit
Connector
Terminal
M8
40
Ground
9.5 - 16.0 V
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
Perform trouble diagnosis of ignition power supply circuit.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector.
- Check the continuity between around view monitor control unit harness connector and ground.
(+)
(-)
Continuity
Around view monitor control unit
Connector
Terminal
M8
39
Ground
Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace harness or connector.