Diagnosis Procedure
If any of the following malfunctions is found for the trip reset and illumination control switch operation.
- All switches are inoperative
- The specified switch cannot be operated
- CHECK TRIP RESET AND ILLUMINATION CONTROL SWITCH SIGNAL CIRCUIT
Check the trip reset and illumination control switch signal circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair harness or connector.
- CHECK TRIP RESET AND ILLUMINATION CONTROL SWITCH
Perform a unit check for the trip reset and illumination control switch. Refer to Component Inspection .
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER : Removal & Installation .
NG
Replace trip reset and illumination control switch. Refer to TRIP RESET AND ILLUMINATION CONTROL SWITCH : Removal & Installation .