Diagnosis Procedure
The meter control switches are inoperative when pressed.
- CHECK METER CONTROL SWITCH SIGNAL
Check the meter control switch signal. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness or connectors.
- CHECK METER CONTROL SWITCH
Perform a unit check for the meter control switch. Refer to Component Inspection .
Is the inspection result normal?
YES
Replace Combination Meter. Refer to Removal and Installation .
NO
Replace meter control switch. Refer to Removal and Installation .