Diagnosis Procedure
- CHECK ELECTRONIC STABILITY PROGRAM CONTROL UNIT BATTERY POWER SUPPLY
- Turn the ignition switch OFF.
- Disconnect electronic stability program control unit harness connector.
- Check the voltage between electronic stability program control unit harness connector and ground.
+
-
Voltage
(Approx.)
Electronic stability program control unit
Connector
Terminal
E46
1
Ground
Battery voltage
7
25
28
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK ELECTRONIC STABILITY PROGRAM CONTROL UNIT BATTERY POWER SUPPLY CIRCUIT
- Turn the ignition switch OFF.
- Check the 40A fuse (#237).
- Check the 5A fuse (#218).
- Check the 25A fuse (#204).
- Check the 5A fuse (#230).
- Disconnect fuse and fusible link block 1 harness connector.
- Check the continuity between electronic stability program control unit harness connector and fuse and fusible link block 1 harness connector.
Electronic stability program control unit
Fuse and fusible link block 1
Continuity
Connector
Terminal
Connector
Terminal
E46
1
E61
26
Existed
7
E57
22
25
E54
1
28
E56
16
- Check the continuity between electronic stability program control unit harness connector and ground.
Electronic stability program control unit
--
Continuity
Connector
Terminal
E46
1
Ground
No existed
7
25
28
Is the inspection result normal?
YES
Perform trouble diagnosis for battery power supply.
NO
Repair / replace harness, connector, or fuse.
- CHECK ELECTRONIC STABILITY PROGRAM CONTROL UNIT GROUND CIRCUIT
Check the continuity between electronic stability program control unit harness connector and the ground.
Electronic stability program control unit
--
Continuity
Connector
Terminal
E46
13
Ground
Existed
38
Is the inspection result normal?
YES
GO TO 4.
NO
Repair / replace harness, connector, or terminal.
- CHECK TERMINAL
- Check the electronic stability program control unit pin terminals for damage or loose connection with harness connector.
- Check the fuse and fusible link block 1 pin terminals for damage or loose connection with harness connector.
Is the inspection result normal?
YES
Replace the electronic stability program control unit. Refer to Removal and Installation .
NO
Repair / replace harness, connector, or terminal.