DTC B2213-96
- CHECK FREQUENCY COUNTER OF COMBINATION METER
Check frequency counter of combination meter with CONSULT. Refer to CONSULT Function .
Is value of the frequency counter > 10?
YES
Replace combination meter. Refer to Removal and Installation .
NO
Erase DTC.