DTC Detection Logic
|
DTC |
CONSULT screen terms |
DTC detection condition |
|||
|
(Trouble diagnosis content) |
[Malfunction type] |
||||
|
B1707 |
11 |
Back-up lamp lh output signal (Back-up lamp left hand output signal) |
[CIRC SHORT TO GRND] |
Diagnosis condition |
Selector lever is R position |
|
Signal (terminal) |
Back-up lamp LH signal |
||||
|
Threshold |
Harness to the back-up lamp LH is shorted to ground |
||||
|
Diagnosis delay time |
12.5 sec. |
||||
|
15 |
[CIRC SHORT TO BATTERY OR OPEN] |
Diagnosis condition |
Selector lever is R position |
||
|
Signal (terminal) |
Back-up lamp LH signal |
||||
|
Threshold |
Harness to the back-up lamp LH is shorted to battery or open |
||||
|
Diagnosis delay time |
12.5 sec. |
||||