DTC B210D-16
- CHECK BATTERY VOLTAGE
Check battery voltage.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace the malfunctioning parts.
- CHECK FUSE
Check that the following fuse are not blown.
Signal name
Fuse No.
Battery power supply
88
Is the fuse blown (open)?
YES
Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO
GO TO 3.
- CHECK COMBINATION METER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Turn ignition switch ON.
- Check the voltage between combination meter harness connector and ground.
Probe
Standard
Voltage
(Approx.)
(+)
(-)
Combination meter
Connector
Terminal
M32
4
Ground
11.0 V - 15.5 V
Battery voltage
Is the inspection result normal?
YES
Check electrical lines and connectors for loose contact and corrosion.
NO
GO TO 4.
- CHECK BATTERY
Check battery. Refer to Work Procedure .
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace the malfunctioning parts.
- CHECK CHARGING SYSTEM
Check charging system condition. Refer to Work Flow (With EXP-800 NI or GR8-1200 NI) (With EXP-800 NI or GR8-1200 NI) or Work Flow (Without EXP-800 NI or GR8-1200 NI) (Without EXP-800 NI or GR8-1200 NI).
Is the inspection result normal?
YES
Replace combination meter. Refer to Removal and Installation .
NO
Repair or replace the malfunctioning parts.