Diagnosis Procedure
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT
Perform diagnosis of ABS Actuator and Electric Unit (Control Unit) power supply and ground circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace error-detected parts.
- PERFORM THE SELF-DIAGNOSIS
With CONSULT
Perform self-diagnosis for "ABS".
Is any DTC detected?
YES
Check the DTC. Refer to DTC Index .
NO
GO TO 3.
- CHECK ABS WARNING LAMP SIGNAL
With CONSULT
- Select "ABS", "DATA MONITOR" and "ABS WARN LAMP" according to this order.
- Turn the ignition switch OFF.
- Check that data monitor displays "On" for approx. 1 second after ignition switch is turned ON, and then changes to "Off".CAUTION: Never start engine.
Is the inspection result normal?
YES
Check combination meter. Refer to CONSULT Function .
NO
Replace ABS Actuator and Electric Unit (Control Unit). Refer to Removal and Installation .