Component Inspection
- CHECK OPEN/CLOSE SWITCH
- Turn ignition switch OFF.
- Disconnect power window main switch (door mirror remote control switch) connector.
- Check continuity between power window main switch (door mirror remote control switch) terminals.
[Driver side]Power window main switch
(door mirror remote control switch)
Condition
Continuity
Terminal
22
17
Open/close switch
OPEN
Existed
7
20
22
20
CLOSE
7
17
[Passenger side]Power window main switch
(door mirror remote control switch)
Condition
Continuity
Terminal
22
18
Open/close switch
OPEN
Existed
7
21
22
21
CLOSE
7
18
Is the inspection result normal?
YES
INSPECTION END
NO
Replace power window main switch (door mirror remote control switch). Refer to Removal and Installation .