LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2018 >> Q70 5.6 Luxe, RWD >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Door Lock (DTC/Circuit Diagnosis) (Except Hybrid) >> DTC/Circuit Diagnosis >> Trunk Lid Opener Request Switch >> Diagnosis Procedure

Diagnosis Procedure

  1. CHECK TRUNK LID OPENER REQUEST SWITCH OUTPUT SIGNAL 
    1. Turn Ignition Switch OFF.
    2. Disconnect Trunk Lid Opener Request Switch connector.
    3. Check voltage between Trunk Lid Opener Request Switch harness connector and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Trunk Lid Opener Request Switch

      Connector

      Terminal

      T4

      1

      Ground

      12 V

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT 
    1. Disconnect BCM connector.
    2. Check continuity between BCM harness connector and Trunk Lid Opener Request Switch harness connector.

      BCM

      Trunk Lid Opener Request Switch

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M121

      51

      T4

      1

      Existed

    3. Check continuity between BCM harness connector and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M121

      51

      Not existed

    Is the inspection result normal?

    YES

    Replace BCM. Refer to Removal and Installation .

    NO

    Repair or replace harness.

  3. CHECK TRUNK LID OPENER REQUEST SWITCH GROUND CIRCUIT 

    Check continuity between Trunk Lid Opener Request Switch harness connector and ground.

    Trunk Lid Opener Request Switch

    Ground

    Continuity

    Connector

    Terminal

    T4

    2

    Existed

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace harness.

  4. CHECK TRUNK LID OPENER REQUEST SWITCH 

    Refer to Component Inspection .

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Replace Trunk Lid Opener Request Switch.

  5. CHECK INTERMITTENT INCIDENT 

    Refer to Intermittent Incident .

    INSPECTION END