Diagnosis Procedure
- CHECK BCM SIGNAL 1
- Turn Ignition Switch OFF.
- Disconnect Remote Keyless Entry Receiver connector.
- Check voltage between Remote Keyless Entry Receiver harness connector and ground.
(+)
(-)
Voltage (V)
(Approx.)
Remote Keyless Entry Receiver
Connector
Terminal
M104
4
Ground
5
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and Remote Keyless Entry Receiver harness connector.
BCM
Remote Keyless Entry Receiver
Continuity
Connector
Terminal
Connector
Terminal
M123
110
M104
4
Existed
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M123
110
Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
- Reconnect Remote Keyless Entry Receiver connector.
- Check signal between Remote Keyless Entry Receiver harness connector and ground using oscilloscope.
(+)
(-)
Signal
(Reference value)
Remote Keyless Entry Receiver
Connector
Terminal
M104
4
Ground
Is the inspection result normal?
YES
GO TO 4.
NO
Replace Remote Keyless Entry Receiver. Refer to Removal and Installation .
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
- Disconnect BCM connector.
- Disconnect Remote Keyless Entry Receiver connector.
- Check continuity between BCM harness connector and Remote Keyless Entry Receiver harness connector.
BCM
Remote Keyless Entry Receiver
Continuity
Connector
Terminal
Connector
Terminal
M120
18
M104
1
Existed
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M120
18
Not existed
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace harness.
- CHECK BCM SIGNAL 2
- Reconnect BCM connector.
- Check voltage between Remote Keyless Entry Receiver harness connector and ground.
(+)
(-)
Voltage (V)
(Approx.)
Remote Keyless Entry Receiver
Connector
Terminal
M104
2
Ground
5
Is the inspection result normal?
YES
GO TO 7.
NO
GO TO 6.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and Remote Keyless Entry Receiver harness connector.
BCM
Remote Keyless Entry Receiver
Continuity
Connector
Terminal
Connector
Terminal
M123
71
M104
2
Existed
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M123
71
Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL
- Reconnect Remote Keyless Entry Receiver connector.
- Check signal between Remote Keyless Entry Receiver harness connector and ground using oscilloscope.
(+)
(-)
Condition
Signal
(Reference value)
Remote Keyless Entry Receiver
Connector
Terminal
M104
2
Ground
During waiting
When operating either button on the Intelligent Key
Is the inspection result normal?
YES
GO TO 8.
NO
Replace Remote Keyless Entry Receiver. Refer to Removal and Installation .
- CHECK BCM SIGNAL 3
- Disconnect Remote Keyless Entry Receiver connector.
- Check voltage between Remote Keyless Entry Receiver harness connector and ground.
(+)
(-)
Voltage (V)
(Approx.)
Remote Keyless Entry Receiver
Connector
Terminal
M104
3
Ground
5
Is the inspection result normal?
YES
GO TO 10.
NO
GO TO 9.
- CHECK REMOTE KEYLESS ENTRY RECEIVER RSSI SIGNAL CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and Remote Keyless Entry Receiver harness connector.
BCM
Remote Keyless Entry Receiver
Continuity
Connector
Terminal
Connector
Terminal
M120
22
M104
3
Existed
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M120
22
Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER RSSI SIGNAL
- Reconnect Remote Keyless Entry Receiver connector.
- Check signal between Remote Keyless Entry Receiver harness connector and ground using oscilloscope.
(+)
(-)
Condition
Signal
(Reference value)
Remote Keyless Entry Receiver
Connector
Terminal
M104
3
Ground
During waiting
When pressing and holding either button on Intelligent Key
Is the inspection result normal?
YES
GO TO 11.
NO
Replace Remote Keyless Entry Receiver. Refer to Removal and Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
INSPECTION END