Diagnosis Procedure
- CHECK NEUTRAL SWITCH INPUT SIGNAL
- Turn Ignition Switch OFF.
- Disconnect Rear Door Closure Motor Assembly RH connector.
- Check voltage between Rear Door Closure Motor Assembly RH harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Rear Door Closure Motor Assembly RH
Connector
Terminal
D83
3
Ground
5 V
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK NEUTRAL SWITCH CIRCUIT
- Disconnect Rear Door Closure Control Unit RH connector.
- Check continuity between Rear Door Closure Control Unit RH harness connector and Rear Door Closure Motor Assembly RH harness connector.
Rear Door Closure Control Unit RH
Rear Door Closure Motor Assembly RH
Continuity
Connector
Terminal
Connector
Terminal
D85
1
D83
3
Existed
- Check continuity between Rear Door Closure Control Unit RH harness connector and ground.
Rear Door Closure Control Unit RH
Ground
Continuity
Connector
Terminal
D85
1
Not existed
Is the inspection result normal?
YES
Replace Rear Door Closure Control Unit RH. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK NEUTRAL SWITCH GROUND CIRCUIT
Check continuity between Rear Door Closure Control Unit RH harness connector and ground.
Rear Door Closure Motor Assembly RH
Ground
Continuity
Connector
Terminal
D83
4
Existed
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace harness.
- CHECK NEUTRAL SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 5.
NO
Replace Rear Door Closure Motor Assembly RH.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
INSPECTION END