Diagnosis Procedure

  1. CHECK FUSE 
    1. Turn ignition switch OFF.
    2. Check 10 A fuse, [No. 3, located in fuse block (J/B)].

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Replace the blown fuse after repairing the affected circuit if a fuse is blown.

  2. CHECK WIPER REVERSE RELAY CONTROL SIGNAL 

    SYMBOL CONSULT ACTIVE TEST

    1. Turn ignition switch ON.
    2. Select "FRONT WIPER" of IPDM E/R active test item.
    3. With operating the test item, check voltage between IPDM E/R harness connector and ground.

    (+)

    (-)

    Condition

    Voltage (Approx.)

    IPDM E/R

    Connector

    Terminal

    E9

    96

    Ground

    FRONT WIPER

    Lo

    Battery voltage

    Hi

    0 V

    Is the inspection result normal?

    YES

    GO TO 5.

    Fixed at 0 V

    GO TO 3.

    Fixed at battery voltage

    Replace IPDM E/R.

  3. CHECK WIPER REVERSE RELAY POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Remove wiper reverse relay.
    3. Check voltage between wiper reverse relay harness connector and ground.

      Wiper reverse relay

      Ground

      Voltage (Approx.)

      Connector

      Terminal

      E44

      1

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace harness.

  4. CHECK WIPER REVERSE RELAY CONTROL CIRCUIT 
    1. Disconnect IPDM E/R connector.
    2. Check continuity between IPDM E/R harness connector and wiper reverse relay harness connector.

      IPDM E/R

      Wiper reverse relay

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      E9

      96

      E44

      2

      Existed

    3. Check continuity between IPDM E/R harness connector and ground.

      IPDM E/R

      Ground

      Continuity

      Connector

      Terminal

      E9

      96

      Not existed

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    Repair or replace harness.

  5. CHECK WIPER REVERSE RELAY-1 

    Check wiper reverse relay. Refer to Component Inspection 

    Is the inspection result normal?

    YES

    Wiper reverse relay circuit is normal.

    NO

    Replace wiper reverse relay.

  6. CHECK WIPER REVERSE RELAY-2 

    Check wiper reverse relay. Refer to Component Inspection 

    Is the inspection result normal?

    YES

    Replace IPDM E/R.

    NO

    Replace wiper reverse relay.