Diagnosis Procedure
- CHECK HEADLAMP WARNING SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect front combination lamp connector.
- Turn ignition switch ON.
- Check voltage between front combination lamp harness connector and ground.
+
-
Voltage
(Approx.)
Front combination lamp
Connector
Terminal
RH
E49
2
Ground
12 V
LH
E48
Is the inspection result normal?
YES
Replace front combination lamp. Refer to Removal and Installation .
NO
GO TO 2.
- CHECK HEADLAMP WARNING SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check continuity between front combination lamp harness connector and combination meter harness connector.
Front combination lamp
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
RH
E49
2
M53
17
Existed
LH
E48
18
Is the inspection result normal?
YES
Replace combination meter. Refer to Removal and Installation .
NO
Repair or replace harness.