Diagnosis Procedure

  1. CHECK HEADLAMP AIMING MOTOR POWER SUPPLY 
    1. Turn ignition switch OFF.
    2. Disconnect headlamp aiming motor connector.
    3. Turn ignition switch ON.
    4. Check voltage between headlamp aiming motor harness connector and ground.

      +

      -

      Voltage

      Headlamp aiming motor

      Connector

      Terminal

      RH

      E26

      1

      Ground

      Battery voltage

      LH

      E56

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Repair harness or connector between headlamp aiming motor and fuse.

  2. CHECK HEADLAMP AIMING MOTOR GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Check continuity between headlamp aiming motor harness connector and ground.

      Headlamp aiming motor

      --

      Continuity

      Connector

      Terminal

      RH

      E26

      2

      Ground

      Existed

      LH

      E56

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace harness.

  3. CHECK AIMING MOTOR DRIVE SIGNAL 

    SYMBOL With CONSULT

    1. Reconnect headlamp aiming motor connector.
    2. Turn ignition switch ON.
    3. Turn lighting switch 2ND.
    4. Select "LEVELIZER TEST" in "Active Test" mode of "ADAPTIVE LIGHT" using CONSULT.
    5. With operating the test items, check voltage between AFS control unit harness connector and ground.

      +

      -

      Test item

      Voltage

      (Approx.)

      AFS control unit

      Connector

      Terminal

      E70

      22

      Ground

      LEVELIZER TEST

      Peak

      8.75 V

      Origin

      3.75 V

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Fixed at 0 V: GO TO 5.

    NO

    Fixed at battery voltage: GO TO 6.

  4. CHECK AIMING MOTOR DRIVE SIGNAL CIRCUIT (OPEN) 
    1. Turn ignition switch OFF.
    2. Disconnect AFS control unit connector and headlamp aiming motor connector.
    3. Check continuity between AFS control unit harness connector and headlamp aiming motor harness connector.

      AFS control unit

      Headlamp aiming motor

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      RH

      E70

      22

      E26

      3

      Existed

      LH

      E56

    Is the inspection result normal?

    YES

    Replace front combination lamp. Refer to Removal and Installation .

    NO

    Repair or replace harness.

  5. CHECK AIMING MOTOR DRIVE SIGNAL CIRCUIT (SHORT TO GROUND) 
    1. Turn ignition switch OFF.
    2. Disconnect AFS control unit connector and headlamp aiming motor connector.
    3. Check continuity between AFS control unit harness connector and ground.

      AFS control unit

      --

      Continuity

      Connector

      Terminal

      E70

      22

      Ground

      Not existed

    Is the inspection result normal?

    YES

    Replace AFS control unit. Refer to Removal and Installation .

    NO

    Repair or replace harness.

  6. CHECK AIMING MOTOR DRIVE SIGNAL CIRCUIT (SHORT TO BATTERY) 
    1. Turn ignition switch OFF.
    2. Disconnect AFS control unit connector and headlamp aiming motor connector.
    3. Check voltage between AFS control unit harness connector and ground.

      +

      -

      Voltage

      (Approx.)

      AFS control unit

      Connector

      Terminal

      E70

      22

      Ground

      0 V

    Is the inspection result normal?

    YES

    Replace AFS control unit. Refer to Removal and Installation .

    NO

    Repair or replace harness.