Diagnosis Procedure
- CHECK FUSES
- Turn Ignition Switch OFF.
- Check that the following fuses are not blown (open).
Signal name
Fuse No.
Battery power supply
5(15 A)
6 (10 A)
Is the fuse blown (open)?
YES
Replace the blown (open) fuse after repairing the affected circuit.
NO
GO TO 2.
- CHECK POWER SUPPLY CIRCUIT
- Disconnect Trunk Closure Assembly connector.
- Check voltage between Trunk Closure Assembly harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Trunk Closure Assembly
Connector
Terminal
T14
4
Ground
Battery voltage
6
Is the inspection result normal?
YES
GO TO 3.
NO
Repair harness or connector.
- CHECK GROUND CIRCUIT
Check continuity between Trunk Closure Assembly harness connector and ground.
Trunk Closure Assembly
Ground
Continuity
Connector
Terminal
T14
2
Existed
3
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.