Home >> Infiniti >> 2017 >> QX70 RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 191 (Hybrid Battery System (Introduction And Diagnostic Trouble Codes (DTCS)) P0A09-P0C6E) (Hybrid)) >> System Description >> Diagnosis System (LBC) >> Diagnosis Description >> DTC And Freeze Frame Data >> Freeze Frame Data And 1ST Trip Freeze Frame Data

Freeze Frame Data And 1ST Trip Freeze Frame Data

WARNING: This page is about a different car, the 2016 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.

LBC stores the Li-ion battery status, such as voltage, current, temperature, and SOC (state of charge) at malfunction detection.

Data which are stored in the LBC memory, along with the 1st trip DTC, are called 1st trip freeze frame data. The data, stored together with the DTC data, are called freeze frame data and displayed on CONSULT or GST. The 1st trip freeze frame data can only be displayed on the CONSULT screen.

LBC can store three sets of freeze frame data (one set for MIL-illuminating DTC and two sets for non-MIL-illuminating DTC). 1st trip freeze frame data is stored in the LBC memory along with the 1st trip DTC.

For MIL-illuminating DTC, there is no priority for 1st trip freeze frame data and it is updated each time a different 1st trip DTC is detected. However, once freeze frame data (2nd trip detection/MIL on) is stored in the LBC memory, 1st trip freeze frame data is no longer stored. Remember, only one set of freeze frame data can be stored in the LBC.

For non-MIL-illuminating DTC, the freeze frame data of the 1st trip DTC has no priority. Every time another 1st trip DTC is detected after two freeze frame data of the 1st trip DTC are stored, the older freeze frame data is updated. However, once freeze frame data (2nd trip detection/MIL on) is stored in the LBC memory, 1st trip freeze frame data is no longer stored. Remember, only one set of freeze frame data can be stored in the LBC.

The LBC has the following priorities to update the data.

Priority Item
1 Freeze frame data
2 1st trip DTC freeze frame data

Both 1st trip freeze frame data and freeze frame data (along with the DTC) are cleared when the LBC memory is erased. For the procedure for erasing the LBC memory, refer to "How to Erase DTC and 1st Trip DTC" of CONSULT FUNCTION .