12-Module Replacement Procedure
Voltage adjustment under low temperature conditions may require a long time. To prevent this from occurring, it is advisable to adjust voltage under room temperature conditions [20°C +- 10°C (68°F +- 18°F) ].
- INSPECTION BEFORE REPLACEMENT
Check the date of production of all the new modules to see that they are 1-month-old or less.
CAUTION:Never use modules older than one year.
NOTE:The manufacturing date is stamped on the side of module.
YY. MM. DD Y = Year M = Month D = Date Example: 10. 11. 02 = November 2, 2010
Is the production date within 1 month?
YES
Voltage adjustment is not necessary. Assemble and install module to vehicle. Refer to DISASSEMBLY AND ASSEMBLY .
NO
GO TO STEP 2 .
- CHECK CELL VOLTAGE DIFFERENCE AMONG MODULES
- Measure cell voltage of each module, using a module charge balancer.NOTE:
Record measured cell voltage.
- Identify the difference between the maximum voltage and the minimum voltage in the same module, according to the measured cell voltage of each module.
Standard : 100 mV or less CAUTION:Never use module of which cell voltage in the same module is more than 100 mV.
Is the voltage difference 100 mV or less?
YES
GO TO STEP 3 .
NO
After replacing applicable module, GO TO STEP 3 .
- Measure cell voltage of each module, using a module charge balancer.
- CHECK CELL VOLTAGE DIFFERENCE AMONG MODULES
Check all the cell voltages (96 cells) measured at Step 2 to see the voltage difference between the maximum and the minimum.
Standard : 100 mV or less Is the voltage difference 100 mV or less?
YES
Voltage adjustment is not necessary. Assemble and install module to vehicle. Refer to DISASSEMBLY AND ASSEMBLY .
NO
GO TO STEP 4 .
- CHECK ADJUSTMENT VOLTAGE VALUE
- Check all the cell voltages measured at Step 2 to identify the module of which voltage is minimum.NOTE:
CELL VOLTAGE * 8 = MODULE VOLTAGE
- Use the minimum module voltage for the adjustment voltage value of module voltage.CAUTION:
- If the measured minimum module voltage is less than 28.0 V, use 28.0 V for the adjustment voltage.
- Adjustment voltage must be in 100 mV. (Drop all digits less than 100.)
Example: 28.825 V (MINIMUM MODULE VOLTAGE) = 28.800 V (Adjustment voltage value)
Adjustment voltage value : MINIMUM MODULE VOLTAGE
(If MINIMUM VOLTAGE VALUE is less than 28.0 V, use 28.0 V.)
GO TO STEP 5 .
- Check all the cell voltages measured at Step 2 to identify the module of which voltage is minimum.
- CHECK MODULE VOLTAGECAUTION:
For details on the module charge balancer operation, refer to the adjuster operation information.
- Set the new module to the module charge balancer.
- Measure module voltage and compare it with "adjustment voltage value" confirmed in STEP 1
Module voltage is lower than adjustment voltage value
GO TO STEP 7 .
Module voltage is higher than adjustment voltage value
GO TO STEP 6 .
- DISCHARGE OF MODULE VOLTAGECAUTION:
For details on the module charge balancer operation, refer to the adjuster operation information.
Discharge the module to 26.0 V using module charge balancer.
Discharge voltage : 26.0 V GO TO STEP 7 .
- MODULE VOLTAGE ADJUSTMENTCAUTION:
For details on the module charge balancer operation, refer to the adjuster operation information.
- Enter the "adjustment voltage value" in the module charge balancer.
Adjustment voltage value : MINIMUM MODULE VOLTAGE
(If MINIMUM VOLTAGE VALUE is less than 28.0 V, use 28.0 V.) - Start the voltage adjustment.
After module voltage adjustment, GO TO STEP 8 .
- Enter the "adjustment voltage value" in the module charge balancer.
- CHECK CELL VOLTAGE
With CONSULT
- After adjusting the voltage, install the module to the vehicle.
- Select "DATA MONITOR" mode.
- Check the difference between "MAXIMUM CELL VOLTAGE" and "MINIMUM CELL VOLTAGE" to see that the difference is within the specified value.
Standard : 100 mV or less CAUTION:If the difference between the maximum cell voltage and the minimum cell voltage is more than 100 mV, DTC is detected. Be sure to check that the difference is 100 mV or less.
WORK END