Component Inspection
- CHECK METER CONTROL SWITCH UNIT
- Turn the Ignition Switch OFF.
- Disconnect the Meter Control Switch connector.
- Check continuity between the following terminals of the Meter Control Switch.
Combination Meter Operation And Status Continuity Connector Terminal M54 6 2 Press (select) switch
Existed Other than the above Not existed 7 2 Press (enter) switch
Existed Other than the above Not existed 3 2 Press (illumination control) switch
Existed Other than the above Not existed 1 2 Press (illumination control) switch
Existed Other than the above Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace the Meter Control Switch.