Diagnosis Procedure
- CHECK CONNECTOR
Check Combination Meter, Unified Meter And A/C Amp. and terminals (Combination Meter side, Unified Meter And A/C Amp. side, and harness side) for looseness or bent.
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair terminal or connector.
- CHECK CONTINUITY COMMUNICATION CIRCUIT
- Turn Ignition Switch OFF.
- Disconnect Combination Meter connector and Unified Meter And A/C Amp. connector.
- Check continuity between Combination Meter Harness Connector and Unified Meter And A/C Amp. Harness Connector.
Combination Meter Unified Meter And A/C Amp. Continuity Connector Terminal Connector Terminal M53 2 M66 27 Existed 3 7 Existed - Check continuity between Combination Meter Harness Connector and ground.
Combination Meter Ground Continuity Connector Terminal M53 2 Not existed 3 Not existed
Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair harness or connector.
- CHECK UNIFIED METER AND A/C AMP. OUTPUT VOLTAGE
- Turn Ignition Switch OFF.
- Disconnect Combination Meter connector.
- Connect Unified Meter And A/C Amp. connector.
- Turn Ignition Switch ON.
- Check voltage between Unified Meter And A/C Amp. Harness Connector and ground.
Terminals Voltage
(Approx.)(+) (-) Unified Meter A/C Amp. Connector Terminal Ground M66 27 5 V
Is the inspection result normal?
YES
GO TO STEP 4.
NO
Replace Unified Meter And A/C Amp.
- CHECK COMBINATION METER OUTPUT VOLTAGE
- Turn Ignition Switch OFF.
- Disconnect Unified Meter And A/C Amp. connector.
- Connect Combination Meter connector.
- Turn Ignition Switch ON.
- Check voltage between Combination Meter Harness Connector and ground.
Terminals Voltage
(Approx.)(+) (-) Combination Meter Connector Terminal Ground M53 3 5 V
Is the inspection result normal?
YES
INSPECTION END
NO
Replace Combination Meter.