Diagnosis Procedure
- CHECK TRIP A/B RESET SWITCH INPUT SIGNAL
- Turn the Ignition Switch ON.
- Check voltage between the Combination Meter Harness Connector terminals.
Combination Meter Condition Voltage Connector Terminal (+) (-) M53 38 16 When trip A/B reset switch is pressed 0 V Other than the above 5 V
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO STEP 2.
- CHECK TRIP A/B RESET SWITCH SIGNAL CIRCUIT
- Turn the Ignition Switch OFF.
- Disconnect the Combination Meter and Meter Control Switch connectors.
- Check continuity between Combination Meter Harness Connector and trip A/B Reset Switch Harness Connector.
Combination Meter Trip A/B Reset Switch Continuity Connector Terminal Connector Terminal M53 38 M56 1 Existed 16 2 Existed - Check continuity between Combination Meter Harness Connector and ground.
Combination Meter Ground Continuity Connector Terminal M53 38 Not existed 16 Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.