Component Inspection
- CHECK TRIP A/B RESET SWITCH UNIT
- Turn the Ignition Switch OFF.
- Disconnect the trip A/B reset switch connector.
- Check continuity between the trip A/B Reset Switch connector terminals.
Combination Meter Operation And Status Continuity Connector Terminal M56 1 2 Press trip A/B reset switch Existed Other than the above Not existed
Is inspection result normal?
YES
INSPECTION END
NO
Replace the trip A/B reset switch.