Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
Power Source Fuse No. Battery 6 Ignition Switch ON or START 4 Is the inspection result normal?
YES
GO TO STEP 2.
NO
Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
Check voltage between Combination Meter Harness Connector and ground.
Terminals Ignition Switch position Value (Approx.) (+) (-) Combination Meter Terminal Signal name M53 1 Battery power supply Ground OFF Battery voltage 21 Ignition signal ON Battery voltage Is the inspection result normal?
YES
GO TO STEP 3.
NO
Check harness between Combination Meter and fuse.
- CHECK GROUND CIRCUIT
- Turn Ignition Switch OFF.
- Disconnect Combination Meter connector.
- Check continuity between Combination Meter Harness Connector and ground.
Combination Meter Ground Continuity Connector Terminal M53 5 Existed 15 Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.