Physical Values
| Terminal No. (Wire color) |
Description | Condition | Value (Approx.) |
|||
|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | |||
| 1 (W) |
5 (B) |
AC output 2 | Output | Ignition switch ON | AC 120V outlet main switch OFF | 0V |
| AC 120V outlet main switch ON (Using circuit tester) |
AC 120V | |||||
| AC 120V outlet main switch ON (Using oscilloscope) |
Reference value AC 120V |
|||||
| 4 (W) |
Ground | Battery power supply | Input | Ignition switch OFF | Battery voltage | |
| 5 (B) |
1 (W) |
AC output 1 | Output | Ignition switch ON | AC 120V outlet main switch OFF | 0V |
| AC 120V outlet main switch ON (Using circuit tester) |
AC 120V | |||||
| AC 120V outlet main switch ON (Using oscilloscope) |
Reference value AC 120V |
|||||
| 6 (W) |
Ground | AC 120 V outlet main switch | Input | Ignition switch ON | AC 120V outlet main switch OFF | 0V |
| AC 120V outlet main switch ON | 12V | |||||
| 7 (G) |
AC 120 V outlet main switch | Output | Ignition switch ON | AC 120V outlet main switch OFF | 0V | |
| AC 120V outlet main switch ON | 5.2V | |||||
| 8 (B) |
Ground | - | Ignition switch ON | 0V | ||
CAUTION:
- To measure AC 120V output signal, always use the circuit tester or oscilloscope AC range.
Never allow the probes to contact each other.
- Because of modified sine wave output of the AC 120V output signal, voltage cannot be measured accurately without using a circuit tester that can measure true RMS (root mean square).