Component Function Check
- CHECK COMBINATION METER INPUT SIGNAL
Select the "Data Monitor" for the "METER/M&A" and check the "STRG SW INPUT" monitor value.
Condition Value BACK Switch is pressed SW1 MENU UP Switch is pressed SW2 MENU DOWN Switch is pressed SW3 VR Switch is pressed SW4 OK Switch is pressed SW5 VOL DOWN Switch is pressed SW6 VOL UP Switch is pressed SW7 TEL Switch is pressed SW8 DISPLAY BACK Switch is pressed SW9 DISPLAY NEXT Switch is pressed SW10 Other than above NO INPUT Is the inspection result normal?
YES
INSPECTION END
NO
Refer to DIAGNOSIS PROCEDURE .