Component Inspection
- CHECK METER CONTROL SWITCH
- Turn Ignition Switch OFF.
- Disconnect Meter Control Switch connector.
- Check continuity between the following terminals of the Meter Control Switch.
Terminals Condition Continuity Meter Control Switch 6 4 When Illumination Control Switch (+) is pressed Existed Other than the above Not existed 7 When Illumination Control Switch (-) is pressed Existed Other than the above Not existed 5 When Trip Reset Switch is pressed Existed Other than the above Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace Meter Control Switch. Refer to REMOVAL AND INSTALLATION .