Diagnosis Procedure
- CHECK TRUNK LID OPENER INPUT SIGNAL
- Turn Ignition Switch OFF.
- Disconnect Trunk Lid Lock Assembly connector.
- Check voltage between Trunk Lid Lock Assembly harness connector and ground.
(+) (-) Condition Voltage Trunk Lid Lock Assembly Connector Terminal T53 3 Ground Trunk lid opener switch is pressed 9 - 16 V Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and Trunk Lid Lock Assembly harness connector.
BCM Trunk Lid Lock Assembly Continuity Connector Terminal Connector Terminal M15 91 T53 3 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M15 91 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK TRUNK LID OPENER ACTUATOR GROUND CIRCUIT
Check continuity between Trunk Lid Lock Assembly harness connector and ground.
Trunk Lid Lock Assembly Ground Continuity Connector Terminal T53 2 Existed Is the inspection normal?
YES
Replace Trunk Lid Lock Assembly.
NO
Repair or replace harness.