Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:

ELECTRIC_SHOCK Since hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are handled incorrectly. Be sure to follow the correct work procedures when performing inspection and maintenance.

WARNING:
  • Be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses and parts.
  • The removed service plug must always be carried in a pocket of the responsible worker or placed in the tool box during the procedure to prevent the plug from being connected by mistake.
  • Be sure to wear insulating protective equipment before beginning work on the high voltage system.
  • Never allow workers other than the responsible person to touch the vehicle containing high voltage parts. To keep others from touching the high voltage parts, these parts must be covered with an insulating sheet except when using them.
  • Refer to HIGH VOLTAGE PRECAUTIONS .
CAUTION:

Never bring the vehicle into the READY status with the service plug removed unless otherwise instructed in the Service Information. A malfunction may occur if this is not observed.

  1. PERFORM SELF-DIAGNOSIS - 1

    G-20 WITH CONSULT

    1. Perform "All DTC Reading" with CONSULT.
    2. Check if the DTC is detected in "Self Diagnostic Result" of "EV/HEV" and "MOTOR CONTROL".
      NOTE:

      Some HPCM DTCs may be detected as a result of the detection of P3030 by LBC. If a DTC detected by HPCM is applicable to the above mentioned DTCs, then judge that DTCs are not detected by HPCM.

      Refer to INDEX OF HPCM-DETECTED DTC for details.

    Is DTC detected?

    YES 

    Perform diagnosis procedure of applicable DTC.

    NO 

    GO TO STEP 2  .

  2. PERFORM SELF-DIAGNOSIS - 2

    G-20 WITH CONSULT

    Check if the "P0A7F" or "P3374" is detected in "Self Diagnostic Result" of "HV BAT"

    Is P0A7F or P3374 detected?

    YES 

    Perform diagnosis procedure of applicable DTC. Refer to the following.

    NO 

    GO TO STEP 3  .

  3. CHECK CELL VOLTAGE-1

    G-20 WITH CONSULT

    Check "CELL VOLTAGE 01-96" in "DATA MONITOR" mode.

    Is the inspection result normal?

    When "DATA MONITOR" works normally 

    GO TO STEP 4  .

    When "DATA MONITOR" works but has a malfunction 

    GO TO STEP 6  .

    When "DATA MONITOR" does not work 

    GO TO STEP 17  .

  4. PRECONDITIONING-1

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 5  .

  5. CHECK HARNESS-1

    1. Remove Li-ion battery. Refer to REMOVAL AND INSTALLATION .
    2. Disconnect harness connectors of Li-ion battery controller and each module.
      CAUTION:

      Check the connection condition before disconnecting harness connector.

    3. Check continuity between Li-ion battery controller harness connector and cell (module) harness connector.
      Module No. Cell No. Module Li-ion battery controller Continuity
      Connector Terminal Connector Terminal
      Module 1 Cell 1 LB8 1 LB3 50 Existed
      Cell 3 3 51
      Cell 5 5 52
      Cell 7 7 53
      Cell 2 LB7 2 LB3 34
      Cell 4 4 35
      Cell 6 6 36
      Cell 8 8 37
      Module 2 Cell 9 LB10 1 LB3 54 Existed
      Cell 11 3 55
      Cell 13 5 56
      Cell 15 7 57
      Cell 10 LB9 2 LB3 38
      Cell 12 4 39
      Cell 14 6 40
      Cell 16 8 42
      Module 3 Cell 17 LB12 1 LB3 58 Existed
      Cell 19 3 59
      Cell 21 5 60
      Cell 23 7 61
      Cell 18 LB11 2 LB3 43
      Cell 20 4 44
      Cell 22 6 45
      Cell 24 8 46
      Module 4 Cell 25 LB14 1 LB3 62 Existed
      Cell 27 3 63
      Cell 29 5 LB4 77
      Cell 31 7 78
      Cell 26 LB13 2 LB3 47
      Cell 28 4 48
      Cell 30 6 LB4 65
      Cell 32 8 66
      Module 5 Cell 33 LB16 1 LB4 80 Existed
      Cell 35 3 81
      Cell 37 5 82
      Cell 39 7 83
      Cell 34 LB15 2 LB4 69
      Cell 36 4 70
      Cell 38 6 71
      Cell 40 8 72
      Module 6 Cell 41 LB18 1 LB4 84 Existed
      Cell 43 3 85
      Cell 45 5 86
      Cell 47 7 87
      Cell 42 LB17 2 LB4 73
      Cell 44 4 74
      Cell 46 6 75
      Cell 48 8 76
      Module 7 Cell 49 LB20 1 LB5 110 Existed
      Cell 51 3 111
      Cell 53 5 112
      Cell 55 7 113
      Cell 50 LB19 2 LB5 90
      Cell 52 4 91
      Cell 54 6 92
      Cell 56 8 93
      Module 8 Cell 57 LB22 1 LB5 114 Existed
      Cell 59 3 115
      Cell 61 5 116
      Cell 63 7 117
      Cell 58 LB21 2 LB5 94
      Cell 60 4 95
      Cell 62 6 96
      Cell 64 8 97
      Module 9 Cell 65 LB24 1 LB5 118 Existed
      Cell 67 3 119
      Cell 69 5 120
      Cell 71 7 121
      Cell 66 LB23 2 LB5 99
      Cell 68 4 100
      Cell 70 6 101
      Cell 72 8 102
      Module 10 Cell 73 LB26 1 LB5 122 Existed
      Cell 75 3 123
      Cell 77 5 124
      Cell 79 7 125
      Cell 74 LB25 2 LB5 103
      Cell 76 4 104
      Cell 78 6 105
      Cell 80 8 106
      Module 11 Cell 81 LB28 1 LB5 127 Existed
      Cell 83 3 128
      Cell 85 5 LB6 137
      Cell 87 7 138
      Cell 82 LB27 2 LB5 107
      Cell 84 4 108
      Cell 86 6 LB6 130
      Cell 88 8 131
      Module 12 Cell 89 LB30 1 LB6 140 Existed
      Cell 91 3 141
      Cell 93 5 142
      Cell 95 7 143
      Cell 90 LB29 2 LB6 132
      Cell 92 4 133
      Cell 94 6 134
      Cell 96 8 135

    Is the inspection result normal?

    YES 

    Replace Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY .

    NO 

    Repair harness or connector.

  6. CHECK CELL VOLTAGE-2

    G-20 WITH CONSULT

    Check if the voltage fluctuation pattern of abnormal cells applies to any one of the conditions below.

    • The voltage of four serial cells respectively drops almost equally (1 - 4, 5 - 8, 9 - 12, 13 - 16, 17 - 20, 21 - 24, 25 - 28, 29 - 32, 33 - 36, 37 - 40, 41 - 44, 45 - 48, 49 - 52, 53 - 56, 57 - 60, 61 - 64, 65 - 68, 69 - 72, 73 - 76, 77 - 80, 81 - 84, 85 - 88, 89 - 92, 93 - 96).
      GNSJSCIA1683GB-683Courtesy of NISSAN NORTH AMERICA, INC.
    • The voltage of three serial cells respectively fluctuates almost equally or in a staircase pattern (1 - 3, 5 - 7, 9 - 11, 13 - 15, 17 - 19, 21 - 23, 25 - 27, 29 - 31, 33 - 35, 37 - 39, 41 - 43, 45 - 47, 49 - 51, 53 - 55, 57 - 59, 61 - 63, 65 - 67, 69 - 71, 73 - 75, 77 - 79, 81 - 83, 85 - 87, 89 - 91, 93 - 95).
      GNSJSCIA1684GB-684Courtesy of NISSAN NORTH AMERICA, INC.
    • The potential difference between two adjacent cells fluctuates unsymmetrically.
      GNSJSCIA1685GB-685Courtesy of NISSAN NORTH AMERICA, INC.
    • The potential difference of two adjacent cells fluctuates symmetrically.
      GNSJSCIA1686GB-686Courtesy of NISSAN NORTH AMERICA, INC.

    Does the voltage fluctuation pattern of abnormal cells apply to any one of the above conditions?

    When the voltage of four serial cells respectively drops almost equally 

    GO TO STEP 7  .

    When the voltage of three serial cells respectively fluctuates almost equally or in a staircase pattern, the potential difference of two adjacent cells fluctuates unsymmetrically, or it fluctuates symmetrically 

    GO TO STEP 12 

    When it does not apply to any one of them 

    GO TO STEP 14  .

  7. PRECONDITIONING-2

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 8  .

  8. CHECK HARNESS-2

    1. Remove Li-ion battery. Refer to REMOVAL AND INSTALLATION .
    2. Disconnect harness connectors of Li-ion battery controller and module including an abnormal cell.
      CAUTION:

      Check the connection condition before disconnecting harness connector.

    3. Check continuity between Li-ion battery controller harness connector and cell (module) harness connector.
      Module No. Cell No. Module Li-ion battery controller Continuity
      Connector Terminal Connector Terminal
      Module 1 Cell 1 LB8 1 LB3 50 Existed
      Cell 3 3 51
      Cell 5 5 52
      Cell 7 7 53
      Cell 2 LB7 2 LB3 34
      Cell 4 4 35
      Cell 6 6 36
      Cell 8 8 37
      Module 2 Cell 9 LB10 1 LB3 54 Existed
      Cell 11 3 55
      Cell 13 5 56
      Cell 15 7 57
      Cell 10 LB9 2 LB3 38
      Cell 12 4 39
      Cell 14 6 40
      Cell 16 8 42
      Module 3 Cell 17 LB12 1 LB3 58 Existed
      Cell 19 3 59
      Cell 21 5 60
      Cell 23 7 61
      Cell 18 LB11 2 LB3 43
      Cell 20 4 44
      Cell 22 6 45
      Cell 24 8 46
      Module 4 Cell 25 LB14 1 LB3 62 Existed
      Cell 27 3 63
      Cell 29 5 LB4 77
      Cell 31 7 78
      Cell 26 LB13 2 LB3 47
      Cell 28 4 48
      Cell 30 6 LB4 65
      Cell 32 8 66
      Module 5 Cell 33 LB16 1 LB4 80 Existed
      Cell 35 3 81
      Cell 37 5 82
      Cell 39 7 83
      Cell 34 LB15 2 LB4 69
      Cell 36 4 70
      Cell 38 6 71
      Cell 40 8 72
      Module 6 Cell 41 LB18 1 LB4 84 Existed
      Cell 43 3 85
      Cell 45 5 86
      Cell 47 7 87
      Cell 42 LB17 2 LB4 73
      Cell 44 4 74
      Cell 46 6 75
      Cell 48 8 76
      Module 7 Cell 49 LB20 1 LB5 110 Existed
      Cell 51 3 111
      Cell 53 5 112
      Cell 55 7 113
      Cell 50 LB19 2 LB5 90
      Cell 52 4 91
      Cell 54 6 92
      Cell 56 8 93
      Module 8 Cell 57 LB22 1 LB5 114 Existed
      Cell 59 3 115
      Cell 61 5 116
      Cell 63 7 117
      Cell 58 LB21 2 LB5 94
      Cell 60 4 95
      Cell 62 6 96
      Cell 64 8 97
      Module 9 Cell 65 LB24 1 LB5 118 Existed
      Cell 67 3 119
      Cell 69 5 120
      Cell 71 7 121
      Cell 66 LB23 2 LB5 99
      Cell 68 4 100
      Cell 70 6 101
      Cell 72 8 102
      Module 10 Cell 73 LB26 1 LB5 122 Existed
      Cell 75 3 123
      Cell 77 5 124
      Cell 79 7 125
      Cell 74 LB25 2 LB5 103
      Cell 76 4 104
      Cell 78 6 105
      Cell 80 8 106
      Module 11 Cell 81 LB28 1 LB5 127 Existed
      Cell 83 3 128
      Cell 85 5 LB6 137
      Cell 87 7 138
      Cell 82 LB27 2 LB5 107
      Cell 84 4 108
      Cell 86 6 LB6 130
      Cell 88 8 131
      Module 12 Cell 89 LB30 1 LB6 140 Existed
      Cell 91 3 141
      Cell 93 5 142
      Cell 95 7 143
      Cell 90 LB29 2 LB6 132
      Cell 92 4 133
      Cell 94 6 134
      Cell 96 8 135

    Is the inspection result normal?

    YES 

    GO TO STEP 9  .

    NO 

    Repair harness or connector.

  9. CHECK THE HISTORY OF REPLACEMENT-1

    Check the latest replacement history of the module or battery pack assembly.

    Is there a history of part replacement?

    YES-1 

    When there is a history of replacing all of the 12 modules, GO TO STEP 10  .

    YES-2 

    When there is a history of replacing single module, replace all of the 12 modules and Li-ion battery controller. However, when replacing a module replaced in the past, it is possible to replace it as a single module replacement if the Li-ion battery is within 17 months from the manufacturing date. In this case, replace only module including an abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    YES-3 

    When there is a history of battery pack assembly replacement, GO TO STEP 11  .

    NO 

    GO TO STEP 11  .

  10. CHECK THE HISTORY OF REPLACEMENT-2

    Check the module manufacturing date recorded during the replacement of all the 12 modules.

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    NO 

    Replace a module including abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

  11. CHECK THE DATE OF MANUFACTURE OF LI-ION BATTERY-1

    Check the battery pack assembly manufacturing date included in the module serial number label. For the label location, refer to INSPECTION .

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    NO 

    Replace a module including abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

  12. PRECONDITIONING-3

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 13  .

  13. CHECK HARNESS-3

    1. Remove Li-ion battery. Refer to REMOVAL AND INSTALLATION .
    2. Disconnect harness connectors of Li-ion battery controller and module including an abnormal cell.
      CAUTION:

      Check the connection condition before disconnecting harness connector.

    3. Check continuity between Li-ion battery controller harness connector and cell (module) harness connector.
      Module No. Cell No. Module Li-ion battery controller Continuity
      Connector Terminal Connector Terminal
      Module 1 Cell 1 LB8 1 LB3 50 Existed
      Cell 3 3 51
      Cell 5 5 52
      Cell 7 7 53
      Cell 2 LB7 2 LB3 34
      Cell 4 4 35
      Cell 6 6 36
      Cell 8 8 37
      Module 2 Cell 9 LB10 1 LB3 54 Existed
      Cell 11 3 55
      Cell 13 5 56
      Cell 15 7 57
      Cell 10 LB9 2 LB3 38
      Cell 12 4 39
      Cell 14 6 40
      Cell 16 8 42
      Module 3 Cell 17 LB12 1 LB3 58 Existed
      Cell 19 3 59
      Cell 21 5 60
      Cell 23 7 61
      Cell 18 LB11 2 LB3 43
      Cell 20 4 44
      Cell 22 6 45
      Cell 24 8 46
      Module 4 Cell 25 LB14 1 LB3 62 Existed
      Cell 27 3 63
      Cell 29 5 LB4 77
      Cell 31 7 78
      Cell 26 LB13 2 LB3 47
      Cell 28 4 48
      Cell 30 6 LB4 65
      Cell 32 8 66
      Module 5 Cell 33 LB16 1 LB4 80 Existed
      Cell 35 3 81
      Cell 37 5 82
      Cell 39 7 83
      Cell 34 LB15 2 LB4 69
      Cell 36 4 70
      Cell 38 6 71
      Cell 40 8 72
      Module 6 Cell 41 LB18 1 LB4 84 Existed
      Cell 43 3 85
      Cell 45 5 86
      Cell 47 7 87
      Cell 42 LB17 2 LB4 73
      Cell 44 4 74
      Cell 46 6 75
      Cell 48 8 76
      Module 7 Cell 49 LB20 1 LB5 110 Existed
      Cell 51 3 111
      Cell 53 5 112
      Cell 55 7 113
      Cell 50 LB19 2 LB5 90
      Cell 52 4 91
      Cell 54 6 92
      Cell 56 8 93
      Module 8 Cell 57 LB22 1 LB5 114 Existed
      Cell 59 3 115
      Cell 61 5 116
      Cell 63 7 117
      Cell 58 LB21 2 LB5 94
      Cell 60 4 95
      Cell 62 6 96
      Cell 64 8 97
      Module 9 Cell 65 LB24 1 LB5 118 Existed
      Cell 67 3 119
      Cell 69 5 120
      Cell 71 7 121
      Cell 66 LB23 2 LB5 99
      Cell 68 4 100
      Cell 70 6 101
      Cell 72 8 102
      Module 10 Cell 73 LB26 1 LB5 122 Existed
      Cell 75 3 123
      Cell 77 5 124
      Cell 79 7 125
      Cell 74 LB25 2 LB5 103
      Cell 76 4 104
      Cell 78 6 105
      Cell 80 8 106
      Module 11 Cell 81 LB28 1 LB5 127 Existed
      Cell 83 3 128
      Cell 85 5 LB6 137
      Cell 87 7 138
      Cell 82 LB27 2 LB5 107
      Cell 84 4 108
      Cell 86 6 LB6 130
      Cell 88 8 131
      Module 12 Cell 89 LB30 1 LB6 140 Existed
      Cell 91 3 141
      Cell 93 5 142
      Cell 95 7 143
      Cell 90 LB29 2 LB6 132
      Cell 92 4 133
      Cell 94 6 134
      Cell 96 8 135

    Is the inspection result normal?

    YES 

    Replace Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY .

    NO 

    Repair harness or connector.

  14. CHECK THE HISTORY OF REPLACEMENT-3

    Check the latest replacement history of the module or battery pack assembly.

    Is there a history of part replacement?

    YES-1 

    When there is a history of replacing all of the 12 modules, GO TO STEP 15  .

    YES-2 

    When there is a history of replacing single module, replace all of the 12 modules. However, when replacing a module replaced in the past, it is possible to replace it as a single module replacement if the Li-ion battery is within 17 months from the manufacturing date. In this case, replace only module including an abnormal cell. Refer to DISASSEMBLY AND ASSEMBLY .

    YES-3 

    When there is a history of battery pack assembly replacement, GO TO STEP 16  .

    NO 

    GO TO STEP 16  .

  15. CHECK THE HISTORY OF REPLACEMENT-4

    Check the module manufacturing date recorded during the replacement of all the 12 modules.

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules. Refer to DISASSEMBLY AND ASSEMBLY .

    NO 

    Replace a module including abnormal cell. Refer to DISASSEMBLY AND ASSEMBLY .

  16. CHECK THE DATE OF MANUFACTURE OF LI-ION BATTERY-2

    Check the battery pack assembly manufacturing date included in the module serial number label. For the label location, refer to INSPECTION .

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules. Refer to DISASSEMBLY AND ASSEMBLY .

    NO 

    Replace a module including abnormal cell. Refer to DISASSEMBLY AND ASSEMBLY .

  17. PRECONDITIONING-4

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 18  .

  18. CHECK HARNESS-4

    1. Remove Li-ion battery. Refer to REMOVAL AND INSTALLATION .
    2. Disconnect harness connectors of Li-ion battery controller and each module.
      CAUTION:

      Check the connection condition before disconnecting harness connector.

    3. Check continuity between Li-ion battery controller harness connector and cell (module) harness connector.
      Module No. Cell No. Module Li-ion battery controller Continuity
      Connector Terminal Connector Terminal
      Module 1 Cell 1 LB8 1 LB3 50 Existed
      Cell 3 3 51
      Cell 5 5 52
      Cell 7 7 53
      Cell 2 LB7 2 LB3 34
      Cell 4 4 35
      Cell 6 6 36
      Cell 8 8 37
      Module 2 Cell 9 LB10 1 LB3 54 Existed
      Cell 11 3 55
      Cell 13 5 56
      Cell 15 7 57
      Cell 10 LB9 2 LB3 38
      Cell 12 4 39
      Cell 14 6 40
      Cell 16 8 42
      Module 3 Cell 17 LB12 1 LB3 58 Existed
      Cell 19 3 59
      Cell 21 5 60
      Cell 23 7 61
      Cell 18 LB11 2 LB3 43
      Cell 20 4 44
      Cell 22 6 45
      Cell 24 8 46
      Module 4 Cell 25 LB14 1 LB3 62 Existed
      Cell 27 3 63
      Cell 29 5 LB4 77
      Cell 31 7 78
      Cell 26 LB13 2 LB3 47
      Cell 28 4 48
      Cell 30 6 LB4 65
      Cell 32 8 66
      Module 5 Cell 33 LB16 1 LB4 80 Existed
      Cell 35 3 81
      Cell 37 5 82
      Cell 39 7 83
      Cell 34 LB15 2 LB4 69
      Cell 36 4 70
      Cell 38 6 71
      Cell 40 8 72
      Module 6 Cell 41 LB18 1 LB4 84 Existed
      Cell 43 3 85
      Cell 45 5 86
      Cell 47 7 87
      Cell 42 LB17 2 LB4 73
      Cell 44 4 74
      Cell 46 6 75
      Cell 48 8 76
      Module 7 Cell 49 LB20 1 LB5 110 Existed
      Cell 51 3 111
      Cell 53 5 112
      Cell 55 7 113
      Cell 50 LB19 2 LB5 90
      Cell 52 4 91
      Cell 54 6 92
      Cell 56 8 93
      Module 8 Cell 57 LB22 1 LB5 114 Existed
      Cell 59 3 115
      Cell 61 5 116
      Cell 63 7 117
      Cell 58 LB21 2 LB5 94
      Cell 60 4 95
      Cell 62 6 96
      Cell 64 8 97
      Module 9 Cell 65 LB24 1 LB5 118 Existed
      Cell 67 3 119
      Cell 69 5 120
      Cell 71 7 121
      Cell 66 LB23 2 LB5 99
      Cell 68 4 100
      Cell 70 6 101
      Cell 72 8 102
      Module 10 Cell 73 LB26 1 LB5 122 Existed
      Cell 75 3 123
      Cell 77 5 124
      Cell 79 7 125
      Cell 74 LB25 2 LB5 103
      Cell 76 4 104
      Cell 78 6 105
      Cell 80 8 106
      Module 11 Cell 81 LB28 1 LB5 127 Existed
      Cell 83 3 128
      Cell 85 5 LB6 137
      Cell 87 7 138
      Cell 82 LB27 2 LB5 107
      Cell 84 4 108
      Cell 86 6 LB6 130
      Cell 88 8 131
      Module 12 Cell 89 LB30 1 LB6 140 Existed
      Cell 91 3 141
      Cell 93 5 142
      Cell 95 7 143
      Cell 90 LB29 2 LB6 132
      Cell 92 4 133
      Cell 94 6 134
      Cell 96 8 135

    Is the inspection result normal?

    YES 

    GO TO STEP 19  .

    NO 

    Repair harness or connector.

  19. CHECK ALL CELLS VOLTAGE

    Check voltage of all cells. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    Replace Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY .

    NO 

    GO TO STEP 20  .

  20. CHECK THE HISTORY OF REPLACEMENT-5

    Check the latest replacement history of the module or battery pack assembly.

    Is there a history of part replacement?

    YES-1 

    When there is a history of replacing all of the 12 modules, GO TO STEP 21  .

    YES-2 

    When there is a history of replacing single module, replace all of the 12 modules and Li-ion battery controller. However, when replacing a module replaced in the past, it is possible to replace it as a single module replacement if the Li-ion battery is within 17 months from the manufacturing date. In this case, replace only module including an abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    YES-3 

    When there is a history of battery pack assembly replacement, GO TO STEP 22  .

    NO 

    GO TO STEP 22  .

  21. CHECK THE HISTORY OF REPLACEMENT-6

    Check the module manufacturing date recorded during the replacement of all the 12 modules.

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    NO 

    Replace a module including abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

  22. CHECK THE DATE OF MANUFACTURE OF LI-ION BATTERY-3

    Check the battery pack assembly manufacturing date included in the module serial number label. For the label location, refer to INSPECTION .

    Is it more than 17 months from the date of manufacture?

    YES 

    Replace all of the 12 modules and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).

    NO 

    Replace a module including abnormal cell and Li-ion battery controller. Refer to DISASSEMBLY AND ASSEMBLY (Module) or DISASSEMBLY AND ASSEMBLY (Li-ion battery controller).