Home >> Infiniti >> 2017 >> Q50 Base, RWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Power Supply, Ground & Circuit Elements (Except Hybrid) >> Basic Inspection >> Battery Inspection >> 2.0L Turbo Gasoline Engine >> Work Flow >> Sub Battery

Sub Battery

  1. CHECK BATTERY (USE CONSULT)

    Check the battery, using CONSULT. Refer to DIAGNOSIS PROCEDURE .

    Is the check result normal?

    YES 

    GO TO STEP 2. 

    NO 

    Replace battery. Refer to REMOVAL AND INSTALLATION .

  2. CHECK BATTERY (USE EXP-800 NI OR GR8-1200 NI)

    Check the battery, using EXP-800 NI OR GR8-1200 NI.

    Is the check result normal?

    YES 

    INSPECTION END (The battery is normal.)

    NO 

    Replace battery. Refer to REMOVAL AND INSTALLATION .

BATTERY DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI

To diagnose and confirm the condition of the battery, use the following special service tools:

NOTE:

Refer to the applicable instruction information for proper battery diagnosis procedures.

CAUTION:

For gas leakage, remove the 12V battery from the vehicle to charge in a well-ventilated area.

BATTERY DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI

Check the Battery Indicator

Check the indicator placed at the top of battery to judge the battery state. If the battery state is "CHARGING NECESSARY" charge the battery according to "Charging The Battery".

G08902641Courtesy of NISSAN NORTH AMERICA, INC.
NOTE:

If indicator is hard to check, remove battery from vehicle.

Charging The Battery

CAUTION:
  • For gas leakage, remove the battery from the vehicle to charge in a well-ventilated area.
  • There are two charging methods: Quick charging and standard charging.

    "Standard charging" is used for recovering the state of charge.

    "Quick charging" restores the battery to the state capable of engine start and the READY state.

  • Never "quick charge" a fully discharged battery.
  • Keep the battery away from open flame while it is being charged.
  • When connecting the charger, connect the leads first, then turn on the charger. Never turn on the charger first, as this may cause a spark.
  • While charging the battery, maintain 12V battery temperature as follows:

    Standard charging: 45 °C (113 °F) or less

    Quick charging: 55 °C (131 °F) or less

  • Maintain charging voltage at 15 V or less during battery charge.
CHARGING RATES (STANDARD CHARGE)

Approximate charge condition Charge current (A) Charge time (h)
Fully charged 5 2
3/4 charged 2.5
1/2 charged 5
1/4 charged 7.5
Almost discharged 9
Completely discharged 10
CHARGING RATES (QUICK CHARGE)

Approximate charge condition Charge current (A) Charge time (h)
Fully charged - -
3/4 charged 13 0.5
1/2 charged 26
1/4 charged
Almost discharged
Completely discharged - -
NOTE:
  • The battery indicator shows "OK" at the completion of battery charging.
  • The ammeter reading on your battery charger will automatically decrease as the battery charges. This indicates that the voltage of the battery is increasing normally as the state of charge improves. The charging amps indicated above refer to initial charge rate.