Component Inspection
- CHECK CHANGEOVER SWITCH
- Turn ignition switch OFF.
- Disconnect power window main switch (door mirror remote control switch) connector.
- Check continuity between power window main switch (door mirror remote control switch) terminals.
Power window main switch (door mirror remote control switch) Condition Continuity Terminal 23 7 Changeover switch LEFT Existed Other than the above Not existed 28 RIGHT Existed Other than the above Not existed Is the inspection result normal?
YES
INSPECTION END
NO
Replace power window main switch (door mirror remote control switch). Refer to REMOVAL AND INSTALLATION .