LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2017 >> Q50 Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 240 (Hybrid Motor System (Diagnostic Trouble Codes (DTCS) P0A02-U1002) (Hybrid)) >> DTC Diagnosis >> Insulation Resistance >> Component Inspection

Component Inspection

WARNING: This page is about a different car, the 2016 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:

ELECTRIC_SHOCK Since hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are handled incorrectly. Be sure to follow the correct work procedures when performing inspection and maintenance.

WARNING:
  • Be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses and parts.
  • The removed service plug must always be carried in a pocket of the responsible worker or placed in the tool box during the procedure to prevent the plug from being connected by mistake.
  • Be sure to wear insulating protective equipment before beginning work on the high voltage system.
  • Never allow workers other than the responsible person to touch the vehicle containing high voltage parts. To keep others from touching the high voltage parts, these parts must be covered with an insulating sheet except when using them.
  • Refer to HIGH VOLTAGE PRECAUTIONS .
CAUTION:

Never bring the vehicle into the READY status with the service plug removed unless otherwise instructed in the Service information. A malfunction may occur if this is not observed.

  1. PRECONDITIONING

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 2  .

  2. CHECK TRACTION MOTOR INSULATION RESISTANCE

    WARNING:

    Unlike the ordinary tester, the insulation resistance tester applies 500V when measuring. If used incorrectly, there is the danger of electric shock. If used in the vehicle 12V system, there is the danger of damage to electronic devices. Read the insulation resistance tester instruction manual carefully and be sure to work safely.

    1. Disconnect the 3-phase harness from the traction motor inverter. Refer to REMOVAL AND INSTALLATION .
    2. Use 500V range of insulation resistance tester to measure insulation resistance. Wait for 30 seconds until the value becomes stable.
      CAUTION:

      Be sure to set the insulation resistance tester to 500V when performing this test. Using a setting higher than 500V can result in damage to the component being inspected.

      Traction motor inverter 3-phase Ground Resistance
      Connector Terminal
      H21 U Transmission housing case 20 MΩ or more
      V
      W

    Is the inspection result normal?

    YES 

    INSPECTION END

    NO 

    Replace the transmission assembly due to malfunction in the traction motor. Refer to REMOVAL AND INSTALLATION .