Diagnostic Test
- CHECK POWER SOURCE (PART 1)
- Turn ignition switch OFF.
- Disconnect stop lamp switch connector.
- Turn ignition switch ON.
- Check voltage between stop lamp switch harness connector terminal and ground.
+ - Voltage
(Approx.)Stop lamp switch Connector Terminal E57 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
GO TO STEP 8 .
- CHECK STOP LAMP SWITCH MOUNTING POSITION
Check stop lamp switch mounting position. Refer to INSPECTION AND ADJUSTMENT .
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Adjust stop lamp switch mounting position.
- CHECK STOP LAMP SWITCH
Check stop lamp switch. Refer to COMPONENT INSPECTION (STOP LAMP SWITCH) .
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN STOP LAMP SWITCH AND SHIFT SELECTOR (PART 1)
- Disconnect A/T shift selector connector.
- Check continuity between stop lamp switch harness connector terminal and A/T shift selector harness connector terminal.
Stop lamp switch A/T shift selector Continuity Connector Terminal Connector Terminal E57 2 M7 8 Existed
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN STOP LAMP SWITCH AND SHIFT SELECTOR (PART 2)
Check continuity between stop lamp switch harness connector terminal and ground.
Stop lamp switch - Continuity Connector Terminal E57 2 Ground Not existed Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace damaged parts.
- CHECK GROUND CIRCUIT
Check continuity between A/T shift selector harness connector terminal and ground.
A/T shift selector - Continuity Connector Terminal M7 4 Ground Existed Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace damaged parts.
- CHECK SHIFT LOCK UNIT
Check shift lock unit. Refer to COMPONENT INSPECTION (SHIFT LOCK UNIT) .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN FUSE BLOCK (J/B) AND STOP LAMP SWITCH
- Turn ignition switch OFF and wait for 10 minutes or more.
- Disconnect the sub electric oil pump inverter connector.
- Disconnect fuse block (J/B) connector.
- Check continuity between fuse block (J/B) harness connector terminal and stop lamp switch harness connector terminal.
Fuse block (J/B) Stop lamp switch Continuity Connector Terminal Connector Terminal E65 9H E57 1 Existed - Also check short circuit in harness.
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
Repair or replace damaged parts.
- DETECT MALFUNCTIONING ITEM
Check the following items:
- Open circuit or short circuit in harness between ignition switch and fuse block (J/B). Refer to WIRING DIAGRAM - IGNITION POWER SUPPLY - .
- 10A fuse [No. 12, fuse block (J/B) ]. Refer to FUSE, CONNECTOR AND TERMINAL ARRANGEMENT .
- Fuse block (J/B)
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Repair or replace damaged parts.