LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2017 >> Q50 Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 175 (Automatic Transmission (Diagnostic Trouble Codes (DTCS) P0750-P2807 And Circuit Diagnosis) (Hybrid)) >> DTC / Circuit Diagnosis >> Main Power Supply And Ground Circuit (Sub Electric Oil Pump Inverter) >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.

  1. CHECK POWER SUPPLY CIRCUIT

    Check voltage between sub electric oil pump inverter harness connector terminal and ground.

    + - Condition Voltage
    (Approx.)
    Sub electric oil pump inverter
    Connector Terminal
    T1 2 Ground Turn ignition switch ON 9 - 16 V
    Turn ignition switch OFF 0 V

    Is the inspection result normal?

    YES 

    GO TO STEP 4. 

    NO 

    GO TO STEP 2. 

  2. CHECK HARNESS BETWEEN SUB ELECTRIC OIL PUMP INVERTER AND IPDM E/R

    1. Turn ignition switch OFF and wait for 10 minutes or more.
    2. Disconnect the sub electric oil pump inverter connector.
    3. Disconnect the IPDM E/R connector.
    4. Check continuity between sub electric oil pump inverter harness connector terminal and IPDM E/R harness connector terminal.
      Sub electric oil pump inverter IPDM E/R Continuity
      Connector Terminal Connector Terminal
      T1 2 E124 64 Existed
    5. Also check short circuit in harness.

    Is the inspection result normal?

    YES 

    GO TO STEP 3. 

    NO 

    Repair or replace damaged parts.

  3. DETECT MALFUNCTIONING ITEM

    Check the following items:

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Repair or replace damaged parts.

  4. CHECK GROUND CIRCUIT

    1. Turn ignition switch OFF and wait for 10 minutes or more.
    2. Disconnect the sub electric oil pump inverter connector.
    3. Check continuity between sub electric oil pump inverter harness connector terminal and ground.
      Sub electric oil pump inverter - Continuity
      Connector Terminal
      T2 5 Ground Existed

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Repair or replace damaged parts.