LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2017 >> Q50 Base, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 175 (Automatic Transmission (Diagnostic Trouble Codes (DTCS) P0750-P2807 And Circuit Diagnosis) (Hybrid)) >> DTC / Circuit Diagnosis >> DTC P1884: Sub Electric Oil Pump >> Diagnosis Procedure >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2016 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.

  1. CHECK SUB ELECTRIC OIL PUMP INPUT SIGNAL

    1. Turn ignition switch OFF and wait for 10 minutes or more.
    2. Disconnect the negative terminal from 12V battery.
    3. Disconnect sub electric oil pump connector.
    4. Check continuity between sub electric oil pump harness connector terminals.
      Sub electric oil pump Continuity
      Connector Terminal
      C22 1 - 2 Not existed
      1 - 3
      2 - 3
    5. Check continuity between sub electric oil pump harness connector terminals and ground.
      Sub electric oil pump - Continuity
      Connector Terminal
      C22 1 Ground Not existed
      2
      3

    Is the inspection result normal?

    YES 

    GO TO STEP 4. 

    NO 

    GO TO STEP 2. 

  2. CHECK SUB ELECTRIC OIL PUMP INVERTER

    1. Remove sub electric oil pump inverter. Refer to REMOVAL AND INSTALLATION .
    2. Check continuity between sub electric oil pump inverter connector terminals.
      Sub electric oil pump inverter Continuity
      + -
      Terminal
      6 7 Not existed
      9
      10
      Sub electric oil pump inverter Continuity
      + -
      Terminal
      7 5 Not existed
      9
      10

    Is the inspection result normal?

    YES 

    GO TO STEP 3. 

    NO 

    Replace sub electric oil pump inverter. Refer to REMOVAL AND INSTALLATION .

  3. CHECK HARNESS BETWEEN SUB ELECTRIC OIL PUMP INVERTER AND SUB ELECTRIC OIL PUMP

    1. Check continuity between sub electric oil pump inverter harness connector terminals and sub electric oil pump harness connector terminals.
      Sub electric oil pump inverter Sub electric oil pump Continuity
      Connector Terminal Connector Terminal
      H3 9 C22 1 Not existed
      2
      H4 7 1
      3
      10 2
      3
    2. Check continuity between sub electric oil pump inverter harness connector terminals and ground.
      Sub electric oil pump inverter - Continuity
      Connector Terminal
      H3 9 Ground Not existed
      H4 7
      10

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Repair or replace damaged parts.

  4. CHECK SUB ELECTRIC OIL PUMP INSULATION RESISTANCE

    Use an insulation resistance tester to measure insulation resistance.

    Sub electric oil pump - Resistance
    (Approx.)
    Terminal
    1 Housing case 1 MΩ or more
    2
    3

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Replace transmission assembly due to malfunction in sub electric oil pump. Refer to REMOVAL AND INSTALLATION .