Diagnosis Procedure
- CHECK CONNECTOR
Check combination meter, unified meter and A/C amp. and terminals (combination meter side, unified meter and A/C amp. side, and harness side) for looseness or bent.
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair terminal or connector.
- CHECK CONTINUITY COMMUNICATION CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and unified meter and A/C amp. connector.
- Check continuity between combination meter harness connector and unified meter and A/C amp. harness connector.
Combination meter Unified meter and A/C amp. Continuity Connector Terminal Connector Terminal M53 24 M66 14 Existed 25 34 Existed - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M53 24 Not existed 25 Not existed
Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair harness or connector.
- CHECK UNIFIED METER AND A/C AMP. OUTPUT VOLTAGE
- Connect unified meter and A/C amp. connector.
- Turn ignition switch ON.
- Check voltage between unified meter and A/C amp. harness connector and ground.
Terminals Voltage
(Approx.)(+) (-) Unified meter A/C amp. Connector Terminal Ground M66 14 12 V
Is the inspection result normal?
YES
GO TO STEP 4.
NO
Replace unified meter and A/C amp.
- CHECK COMBINATION METER OUTPUT VOLTAGE
- Turn ignition switch OFF.
- Disconnect unified meter and A/C amp. connector.
- Connect combination meter connector.
- Turn ignition switch ON.
- Check voltage between combination meter harness connector and ground.
Terminal Voltage
(Approx.)(+) (-) Combination meter Connector Terminal Ground M53 25 5 V
Is the inspection result normal?
YES
INSPECTION END
NO
Replace combination meter.