Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FUSE
Check that the following fuses are not blown.
Terminal No. Signal name Fuse No. 12 Ignition signal 29 (5A) Are the fuses blown?
YES
Replace the blown fuse after repairing the affected circuit.
NO
GO TO STEP 2 .
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect sonar control unit connector M70.
- Check voltage between sonar control unit connector M70 and ground.
Sonar control unit Ground Condition Voltage
(Approx.)Connector Terminal M70 12 - Ignition switch: ON Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between sonar control unit connector M70 and ground.
Sonar control unit Ground Continuity Connector Terminal M70 15 - Yes
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connectors.