Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FUSE
Check that the following fuse is not blown.
Terminal No. Signal name Fuse No. 3 ACC power supply 65 (10A) Is the fuse blown?
YES
Replace the blown fuse after repairing the affected circuit.
NO
GO TO STEP 2 .
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect multifunction switch connector.
- Check voltage between multifunction switch connector M98 terminal 3 and ground.
Multifunction switch Ground Condition Voltage
(Approx.)Connector Terminal M98 3 - Ignition switch: ACC Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness or connectors.
- CHECK CONTROL UNIT GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect AV control unit connector M164.
- Check continuity between multifunction switch connector M98 terminal 9 and AV control unit connector M164 terminal 98.
Multifunction switch AV control unit Continuity Connector Terminal Connector Terminal M98 9 M164 98 Yes
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness or connectors.
- CHECK SWITCH GROUND CIRCUIT
Check continuity between multifunction switch connector M98 terminal 1 and ground.
Multifunction switch Ground Continuity Connector Terminal M98 1 - Yes Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connectors.