Operation Procedure

  1. Turn ignition switch ON, and switch the trip meter to "trip A" or "trip B".
    NOTE:

    If the diagnosis function is activated with "trip A" displayed, the mileage on "trip A" is reset to "0000.0". (The same way for "trip B".)

  2. Turn ignition switch OFF.
  3. While pressing the trip A/B reset switch (1), turn ignition switch ON again.
    G05731208Courtesy of NISSAN NORTH AMERICA, INC.
  4. Make sure that the trip meter displays "0000.0".
  5. Press the trip A/B reset switch at least 3 times. (Within 7 seconds after the ignition switch is turned ON.)
  6. The unified meter control unit is turned to self - diagnosis mode.
    • Displays "888888" (1) and "8888.8" (2) in the information display LCD (3) for approximately 5 seconds and then blinks the segment dots of the information display LCD alternately.
      G05731209Courtesy of NISSAN NORTH AMERICA, INC.
    • Water temperature gauge and fuel gauge return to zero, and at the same time.
    NOTE:
    • Check combination meter power supply and ground circuit when self - diagnosis mode of combination meter does not start. Replace combination meter if normal.
    • If any of the segments is not displayed, replace combination meter.
  7. Each meter activates during pressing trip A/B reset switch.
    G05731210Courtesy of NISSAN NORTH AMERICA, INC.
    NOTE:
    • If any of the meter and gages is not activated, replace combination meter.
    • The figure is reference.