Diagnosis Procedure
- CHECK OIL PRESSURE WARNING LAMP
Perform auto active test. Refer to DIAGNOSIS DESCRIPTION .
Does oil pressure warning lamp blink?
YES
GO TO STEP 2 .
NO
Replace combination meter.
- CHECK IPDM E/R OUTPUT VOLTAGE
- Disconnect the oil pressure switch connector.
- Turn ignition switch ON.
- Check voltage between the oil pressure switch harness connector and ground.
Terminals Voltage (+) (-) Oil pressure switch Ground Connector Terminal F37 1 Approx. 12 V
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 4 .
- CHECK OIL PRESSURE SWITCH UNIT
Perform a unit check for the oil pressure switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
Replace oil pressure switch.
- CHECK OIL PRESSURE SWITCH SIGNAL CIRCUIT
Check the oil pressure switch signal circuit. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
Repair harness or connector.