Diagnosis Procedure
- CHECK CONTINUITY CAMERA IMAGE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and around view monitor control unit connector.
- Check continuity between display unit harness connector and around view monitor control unit harness connector.
Display unit Around view monitor control unit Continuity Connector Terminal Connector Terminal M195 8 B91 47 Existed - Check continuity between display unit harness connector and ground.
Display unit Ground Continuity Connector Terminal M195 8 Not existed
Is inspection result normal?
YES
GO TO STEP 2 .
NO
Repair harness or connector.
- CHECK CAMERA IMAGE SIGNAL
- Connect display unit connector and around view monitor control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.
(+) (-) Condition Reference value Display unit Connector Terminal M195 8 Ground At camera image is displayed.
Is inspection result normal?
YES
Replace display unit. Refer to REMOVAL AND INSTALLATION .
NO
Replace around view monitor control unit. Refer to REMOVAL AND INSTALLATION .