Diagnosis Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and meter control switch connector.
- Check continuity between combination meter harness connector and meter control switch harness connector.
Terminals Continuity Combination meter Meter control switch Connector Terminal Connector Terminal M57 17 M59 4 Existed 18 5 36 6 37 7 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M57 17 Not existed 18 36 37
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair harness or connector.
- CHECK METER CONTROL SWITCH
Check meter control switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Replace combination meter. Refer to REMOVAL AND INSTALLATION .
NO
Replace meter control switch. Refer to REMOVAL AND INSTALLATION .