LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2016 >> Q50 Base, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 123 (Hybrid Motor System (Diagnostic Trouble Codes (DTCS) P2122-P31FF And Circuit Diagnosis) (Hybrid)) >> DTC / Circuit Diagnosis >> DTC P3117: A/C System >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different variant/trim than selected.
CAUTION:

ELECTRIC_SHOCK Since hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are handled incorrectly. Be sure to follow the correct work procedures when performing inspection and maintenance.

WARNING:
  • Be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses and parts.
  • The removed service plug must always be carried in a pocket of the responsible worker or placed in the tool box during the procedure to prevent the plug from being connected by mistake.
  • Be sure to wear insulating protective equipment before beginning work on the high voltage system.
  • Never allow workers other than the responsible person to touch the vehicle containing high voltage parts. To keep others from touching the high voltage parts, these parts must be covered with an insulating sheet except when using them.
  • Refer to HIGH VOLTAGE PRECAUTIONS .
CAUTION:

Never bring the vehicle into the READY status with the service plug removed unless otherwise instructed in the Service Information. A malfunction may occur if this is not observed.

  1. PRECONDITIONING

    WARNING:

    Follow the instructions below before starting the procedure.

    1. Disconnect high voltage circuit. Refer to HOW TO DISCONNECT HIGH VOLTAGE .
    2. Check voltage in high voltage circuit. Refer to CHECK VOLTAGE IN HIGH VOLTAGE CIRCUIT .

    GO TO STEP 2  .

  2. CHECK ELECTRIC COMPRESSOR HIGH VOLTAGE HARNESS CONNECTOR INSULATION RESISTANCE

    1. Disconnect following electric compressor harness connector.
    2. Check the insulation resistance of high voltage harness connector. Refer to INSULATION RESISTANCE .
      Electric compressor
      Connector H1
    3. Check whether there are neither a water infiltration mark nor a defective seal in the high voltage harness connector.

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    Replace high voltage harness connector.

  3. CHECK ELECTRIC COMPRESSOR INSULATION RESISTANCE

    Check insulation resistance of electric compressor. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    Perform INTERMITTENT INCIDENT .

    NO 

    Replace electric compressor. Refer to REMOVAL AND INSTALLATION .