Diagnosis Procedure
- CHECK TCM POWER SOURCE (PART 1)
- Turn ignition switch OFF.
- Disconnect A/T assembly connector.
- Check voltage between A/T assembly harness connector terminal and ground.
+
-
Condition
Voltage
(Approx.)
A/T assembly
Connector
Terminal
E217
2
Ground
Always
Battery voltage
Is the inspection result normal?
YES
GO TO 2 .
NO
GO TO 4 .
- CHECK TCM POWER SOURCE (PART 2)
Check voltage between A/T assembly harness connector terminals and ground.
+
-
Condition
Voltage
(Approx.)
A/T assembly
Connector
Terminal
E217
1
Ground
Turn ignition switch ON
Battery voltage
Turn ignition switch OFF
0 V
6
Turn ignition switch ON
Battery voltage
Turn ignition switch OFF
0 V
Is the inspection result normal?
YES
GO TO 3 .
NO
GO TO 5 .
- CHECK TCM GROUND CIRCUIT
Check continuity between A/T assembly harness connector terminals and ground.
A/T assembly
--
Continuity
Connector
Terminal
E217
5
Ground
Existed
10
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Repair or replace damaged parts.
- DETECT MALFUNCTIONING ITEM (PART 1)
Check the following items:
- Open circuit or short circuit in harness between battery positive terminal and A/T assembly harness connector terminal 2. Refer to Wiring Diagram - BATTERY POWER SUPPLY - .
- Battery
- 10A fuse (No. 83, fuse block). Refer to Fuse, Connector and Terminal Arrangement .
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Repair or replace damaged parts.
- CHECK HARNESS BETWEEN TCM RELAY AND A/T ASSEMBLY
- Turn ignition switch OFF.
- Disconnect TCM relay connector.
- Check continuity between TCM relay harness connector terminal and A/T assembly harness connector terminals.
TCM relay
A/T assembly
Continuity
Connector
Terminal
Connector
Terminal
B136
3
E217
1
Existed
6
- Also check short circuit in harness.
Is the inspection result normal?
YES
GO TO 6 .
NO
Repair or replace damaged parts.
- DETECT MALFUNCTIONING ITEM (PART 2)
Check the following items:
- Open circuit or short circuit in harness between ignition switch and TCM relay. Refer to Wiring Diagram - ACCESSORY POWER SUPPLY - .
- 10A fuse (No. 78, fuse block). Refer to Fuse, Connector and Terminal Arrangement .
- TCM relay.
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Repair or replace damaged parts.