Diagnosis Procedure
- CHECK FUSE
Check that the following fuse is not fusing.
Signal name Fuse No. Power supply 17 (5 A) Is the fuse fusing?
YES
Replace the blown fuse after repairing the affected circuit if a fuse is blown.
NO
GO TO STEP 2 .
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect remote keyless entry receiver connector.
- Check voltage between remote keyless entry receiver harness connector and ground.
(+) (-) Voltage Remote keyless entry receiver Connector Terminal M113 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M13 17 M113 3 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M13 17 Not existed
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK BCM SIGNAL
- Reconnect BCM connector.
- Check voltage between remote keyless entry receiver harness connector and ground.
(+) (-) Voltage Remote keyless entry receiver Connector Terminal M113 2 Ground 9 - 16 V
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 5 .
- CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
BCM Remote keyless entry receiver Continuity Connector Terminal Connector Terminal M16 119 M113 2 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M16 119 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL
- Reconnect remote keyless entry receiver connector.
- Check signal between remote keyless entry receiver harness connector and ground using oscilloscope.
(+) (-) Condition Signal
(Reference value)Remote keyless entry receiver Connector Terminal M113 2 Ground Ignition switch ON Waiting When operating either button on the Intelligent Key
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Replace remote keyless entry receiver.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END