Diagnosis Procedure
- CHECK FUEL FILLER LID LOCK ACTUATOR INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect fuel filler lid lock actuator connector.
- Check voltage between fuel filler lid lock actuator harness connector and ground.
(+) (-) Condition Voltage Fuel filler lid lock actuator Connector Terminal B76 1 Ground Door lock and unlock switch Unlock 9 - 16 V 2 Lock Is the inspection result normal?
YES
Replace fuel filler lid lock actuator.
NO
GO TO STEP 2 .
- CHECK FUEL FILLER LID LOCK ACTUATOR CIRCUIT
- Disconnect BCM, front door lock assembly (driver side) and front door lock assembly (passenger side) connector.
- Check continuity between BCM harness connector and fuel filler lid lock actuator harness connector.
BCM Fuel filler lid lock actuator Continuity Connector Terminal Connector Terminal M17 135 B76 2 Existed 137 1 - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M17 135 Not existed 137
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK BCM OUTPUT SIGNAL
- Connect BCM connector.
- Check voltage between BCM harness connector and ground.
(+) (-) Condition Voltage BCM Connector Terminal M17 135 Ground Door lock and unlock switch Lock 9 - 16 V 137 Unlock Is the inspection result normal?
YES
Check for internal short of front door lock actuators and fuel filler lid lock actuator.
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION .