Diagnostic Test
- CHECK FUSES
- Turn ignition switch OFF.
- Check that the following fuse is not blown (open).VR30DDTT ENGINE MODELS
Signal name Fuse No. Capacity Ignition power supply 14 5 A 2.0L TURBO GASOLINE ENGINE MODELSSignal name Fuse No. Capacity Ignition power supply 77 10 A
Is the fuse blown (open)?
YES
Replace the blown fuse after repairing the affected circuit if a fuse is blown (open).
NO
GO TO STEP 2 .
- CHECK POWER SUPPLY CIRCUIT
- Disconnect AFS control unit connector.
- Turn ignition switch ON.
- Check voltage between AFS control unit harness connector and ground.
+ - Voltage AFS control unit Connector Terminal M4 12 Ground 9 - 16 V
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between AFS control unit harness connector and ground.
AFS control unit - Continuity Connector Terminal M4 11 Ground Existed
Is the inspection result normal?
YES
Power supply and ground circuit are normal.
NO
Repair or replace harness.