Diagnostic Test
- CHECK FUSE
- Turn ignition switch OFF.
- Check that the following fuses are not blown (open).
Unit Location Fuse No. Capacity Parking lamp RH IPDM E/R #60 10 A Parking lamp LH #59
Is the fuse blown (open)?
YES
Replace the blown fuse after repairing the affected circuit if a fuse is blown (open).
NO
GO TO STEP 2 .
- CHECK PARKING LAMP OUTPUT VOLTAGE
With CONSULT
- Disconnect front combination lamp connector.
- Turn ignition switch ON.
- Select "EXTERNAL LAMPS" in "Active Test" mode of "IPDM E/R" using CONSULT.
- With operating the test items, check voltage between IPDM E/R harness connector and ground.
+ - Test item Voltage IPDM E/R Connector Terminal RH E120 9 Ground EXTERNAL LAMPS TAIL 9 - 16 V Off 0 - 1 V LH 10 TAIL 9 - 16 V Off 0 - 1 V
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
- CHECK PARKING LAMP POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and front combination lamp harness connector.
IPDM E/R Front combination lamp Continuity Connector Terminal Connector Terminal RH E120 9 E42 8 Existed LH 10 E41
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK PARKING LAMP GROUND CIRCUIT
Check continuity between parking lamp harness connector and ground.
Front combination lamp - Continuity Connector Terminal RH E42 4 Ground Existed LH E41 Is the inspection result normal?
YES
Replace front combination lamp. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.