Diagnostic Test
- CHECK HAZARD SWITCH SIGNAL INPUT
- Turn ignition switch OFF.
- Disconnect integral switch connector.
- Check voltage between integral switch connector and ground.
+ - Voltage Integral switch Connector Terminal M1 8 Ground
1.1 V
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 2 .
- CHECK HAZARD SWITCH SIGNAL CIRCUIT (OPEN)
- Disconnect BCM connector.
- Check continuity between integral switch harness connector and BCM harness connector.
Integral switch BCM Continuity Connector Terminal Connector Terminal M1 8 M13 36 Existed
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness.
- CHECK HAZARD SWITCH SIGNAL CIRCUIT (SHORT)
Check continuity between integral switch harness connector and ground.
Integral switch - Continuity Connector Terminal M1 8 Ground Not existed Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK HAZARD SWITCH GROUND CIRCUIT
Check continuity between integral switch harness connector and ground.
Integral switch - Continuity Connector Terminal M1 13 Ground Existed Is the inspection result normal?
YES
Replace integral switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.